Product Name: |
TDZ5-WS Low speed centrifuge
|
Supply Ability: |
1000 |
Related proudcts |
blood centrifuge, low speed centrifuge, |
Specifications |
Model TDZ5-WS Max Speed 5500r/min Max RCF 4390ˇÁg Max Capacit |
Price Term: |
FOB |
Port of loading: |
chansgha,shenzhen,shanghai |
Minimum Order |
1set |
Unit Price: |
USD 700~1500 / Set |
|
TDZ5-WS Bench top low speed swing rotor centrifuge Feature: Whether in the emergency room, laboratory, the benchtop blood centrifuge puts fast blood separation at your fingertips, greatly reducing turn-around time. The Platelet Poor Plasma Mode (PPP) provides serum or plasma separations in 2 or 3 minutes. The Platelet Rich Plasma Mode (PRP) provides for the development of platelet rich plasma in only 30 seconds.
Blood Centrifuge Testing Applications PPP Mode (2 or 3 Minute Spin) Coagulation: When an anticoagulated specimen is separated for 2 or 3 minutes the resulting high-quality platelet poor plasma may be used for coagulation studies such as: Prothrombin Time Partial Prothrombin Time Thrombin Fibrinogen. Chemistry: Plasma or serum separated by the PlasmaPrep&©|8482; centrifuge may also be used for chemistry analyte testing. The use of plasma or serum will depend upon the chemistry procedure employed.
PRP Mode (30 Second Spin) The blood centrifuge is designed to remove the red and white blood cells from the plasma in the PRP mode and leave the platelets suspended in the plasma. The resulting platelet rich plasma may then be used for platelet aggregation studies.
FEATURES:
1. Advanced Control System, Excellent separation
1) 10 kinds of Accel/Decel modes can be selected; User can set up the operate parameter by themselves, to achieve the best centrifugal result.
2) Short running function, easy to achieve diversification of centrifugation.
3) speed control technical, high efficiency.
4) Proprietary soft brake control technical, to avoid mix up and ensure get maximum specimen.
2. High Safety, Ease of use
1) Auto-ID instrant rotor identification system, no need to select rotor No.
2) Over temperature, over speed, door and unbalanced protection.
3) Steel body, Stainless steel chamber, Steel Protective sleeve.
4) Can take the rotor with aerosol-tight lid for use with hazardous samples.
3. Friendly Display, Humanity Operate
1) LCD and LED multiple |